Save 20% when you go straight to the source!
Get the most competitive rates without any distributor markups.
We eliminate the extra costs associated with resellers, passing the savings directly to you.
Tailor your portable CO2 fractional laser machine to your specific needs and branding.
Benefit from our rigorous quality control and industry-leading manufacturing standards.
Receive your order quickly and securely with our trusted global logistics partners.
Why pay more for the same technology? As a leading , we eliminate middlemen to pass on direct savings. Unlock our unbeatable factory – direct pricing on s now!
For all kinds of scars, such as surgical scars, burn scars, scald scars, etc., it has remarkable improvement effect.
Can accurately remove freckles, sun spots, age spots, sun spots, chloasma and many other pigmentation problems.
Helps to fade stretch marks and restore smoothness to the skin.
Achieve skin rejuvenation and skin tightening effects, shrink pores, improve nodular acne, and make the skin radiant.
Good for vascular lesions such as capillary hyperplasia and rosacea.
Both fake and real wrinkles can be effectively removed.
Before deciding to undergo a CO2 laser treatment, the patient is required to have an in-depth consultation with a specialized dermatologist or cosmetic surgeon. The physician will take a detailed history of the patient's medical condition, skin concerns, and desired results, and assess whether the patient is a good candidate for the treatment.
Prior to the treatment, the patient's skin is cleansed and a topical anesthetic may be applied to reduce discomfort. During the treatment, the laser emits a concentrated beam of light that is precisely targeted to a specific area of the skin, removing the damaged or aged outer layer of skin. Depending on the size of the area being treated, a single session lasts between 30 - 60 minutes. During the treatment, the skin cells absorb the CO2 laser and the patient may experience a burning sensation or mild discomfort, but the anesthetic is effective in relieving pain.
After the treatment is co2 laser treatment recovery time and the skin begins to heal. Most patients experience redness and mild swelling for 3-7 days and can return to normal activities within a few days by following post-treatment care instructions. During this time, it is important to follow your physician's care recommendations, including the use of prescribed skin care products and sun protection.
The number of treatments and treatment schedule depends on the severity of the patient’s skin problems and the desired results. Generally speaking.
For mild skin problems such as minor fine lines, small amount of pigmentation, 2 – 3 treatments are usually sufficient to achieve significant results, with an interval of 4 – 6 weeks between each treatment.
Moderate skin problems, such as deeper wrinkles, visible scars, or large areas of hyperpigmentation, may require 3 – 5 treatments every 4 – 6 weeks to make up a full course of treatment.
Severe Skin Problems: For severe acne pits and deep scars, more than 5 treatments are often required, with treatments carried out every 4 – 6 weeks depending on the skin’s recovery to achieve gradual improvement.
co2 laser treatment results:
Short – term results: Immediately after the CO₂ laser treatment, the treated skin area may appear slightly red and feel warm. This is a normal reaction as the laser stimulates the skin’s surface. Minor swelling might also occur, which usually subsides within a few hours to a day. In some cases, tiny scabs may form over the treated spots in the following 1 – 2 days. These scabs are part of the skin’s natural healing process. It’s crucial to keep the treated area clean and avoid any scratching or picking during this period.
Long-term results: The treatment stimulates collagen production, which continues to improve the quality of the skin over the following months. Scars, uneven pigmentation and fine lines are further minimized, with optimal results typically achieved 3 – 6 months after the last treatment. Results are long-lasting, but maintenance treatments may be recommended to sustain the effects of the treatment.
CO2 laser price is influenced by a number of factors, such as the area to be treated, the type of laser, the experience of the practitioner, and the location. On average, a single treatment costs between $5,000 and $9,000. For example, a full face treatment costs about $5,000. The larger the treatment area, the higher the cost.
According to market research and feedback from past cooperation, after buy CO2 laser, with the equipment's leading performance and huge market demand, coupled with reasonable pricing strategy and active promotional actions, usually within 6 months to return to profitability, and after that the annual profit margin of up to 30%, to start a stable profit mode.
With pricing of $800 - $1,500 for a single service and an average monthly client flow of 30, CO2 laser cost can be recouped in about 8 months, followed by a net profit of $400,000 - $600,000 per year, making it a stable point of profit growth.
For example, for a full face treatment, a single treatment at a medical institution costs US$5,000, or US$15,000 for three sessions. Purchasing a home CO2 laser on your own can cost as little as $3,000, a long-term savings of more than 80%. However, strict guidelines must be followed to ensure safe and effective treatment.
1.Six-jointed light guide arm
Laser light transmission is accomplished by a six-jointed light guide arm. The purpose of the arm is to transmit the laser light to the area where the patient is to be operated on (the target surface).
2. Scanner
Equipped with a graphic scanner that can scan and output rectangular, circular, hexagonal, triangular and other graphics, scanning a maximum area of about 20×20 square meters.
3. Machine body
It includes high voltage power supply, low voltage power supply, control system, cooling system, laser system and blowing system.
4.Touch display panel
Mainly used for parameter setting
5.Emergency stop switch
It is a button switch. When the instrument has abnormal condition, you can press the emergency stop switch to cut off the power supply system of the instrument.
6.Key switch
When the key is inserted into the key switch and turned to the “on” position, the instrument will be powered on and turned off when it is turned to the “off” position, which will cut off the power and turn off the instrument.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Intimate laser on vaginal laxity is to use 10600nm water absorption gold standard laser, using three-dimensional fractional technology as well as the perfect combination of 360-degree ring emission technology to produce a high temperature of 50-70 degrees Celsius in the controlled depth of the vaginal mucosa, stimulate the fibroblasts in the mucosal lamina propria and myofibroblasts newborn, and restructure the damaged collagen fibers, elastic fibers and so on, so that to achieve the thickening of the vaginal wall, Tightening, so that the tightness of the vagina, the sensitivity of the enhancement of the vagina, the vagina as tight as ever.
The private laser does not produce epidermal burns due to excessive temperatures. It can act on Mucosa tissues of several hundred ho microns thickness with homogeneous thermal energy each time. Adopting the perfect ratio of wavelength and thermal action of C02 laser, the powerful thermal action can make the collagen fibers, elastic fibers, reticular fibers and organic matrix in the vaginal mucosa proliferate in large quantities and re-phase:The principle of C02’s micro-pulsation action makes the vaginal blood vessels reconstructed and the blood flow increased. The cell function is active, which in turn tightens the vagina, enhances secretion and sensitivity, and restores the vagina to a young and healthy state.
The device is equipped with a variety of scanning modes, the number of focal spots, focal spot density, scanning mode can be flexibly adjusted, the doctor can choose the appropriate shape according to the actual treatment area. Whether facing complex lesions or responding to diversified treatment needs, this function enables more accurate energy and position positioning, and quickly and efficiently achieves the treatment goal.
Transmission of laser energy: The generated laser beam is efficiently transmitted from the laser generator to the area to be treated or processed.
Precise positioning and operation: The multi-jointed light guide arm can simulate human arm joints and rotate 360 degrees.
Ensure beam quality: Compression of the laser beam divergence angle ensures high transmission efficiency and beam invisibility, so that the output laser spot has uniform energy distribution and regular shape. Ensure the safety and effectiveness of laser treatment.
Expanding the operation range: extending the action distance of laser to a certain extent, expanding the operation range of laser.
Versatile Fractional Scanner for efficient ablative procedures, ideal for skin texture and pigmentation
The Fractional Scanner is a handheld microprocessor-controlled laser scanner for charcoal-free ablative procedures that provides rapid coverage of large areas. It is designed for a variety of dermatologic, cosmetic and surgical applications. A variety of scanning options are available, including square, rectangular, triangular, hexagonal, circular or elliptical, and straight lines. The maximum area scanned is approximately 20 mm × 20 mm.
The fractional scanner optimizes treatment results by providing higher energy output per pixel in shorter pulses for ablation procedures. The galvanometer scanning motor delivers energy to each scanning area faster than a CO2 focus applicator, resulting in faster and more efficient coverage of large areas.
Combines cutting and coagulation functions into one setting. The synergy between the two allows the surgeon to perform both operations without having to switch applicators or parameters during the procedure.
In “cut” (ablation) mode, the pulse emits high peak power to immediately ablate tissue. In “coagulation” (thermal) mode, longer pulses emit low to moderate power, generating heat that causes blood vessels and tissue to constrict. This sequential action pulse allows the surgeon to achieve optimal tissue dissection or removal with minimal bleeding and reduces patient downtime. Two spot sizes of fixed focus applicators allow for precise soft tissue cutting.
♥ The environment where the instrument is installed and used requires cleanliness, low dust, temperature 5℃-35℃, relative humidity ≤80%, no corrosive particles, conductive dust, etc., and avoid strong magnetic field interference;
♥ Choose a well-ventilated location, not to be placed near heat sources such as radiators, heat ventilation ducts or places prone to mechanical vibration;
♥ In order to ensure the accuracy of the output energy, please keep all parts of the output port of the treatment handpiece clean;
♥ After the instrument is used, wait for 5 minutes and then turn off the power, clean the treatment head and keep it;
♥ When cleaning the treatment room, avoid raising dust as much as possible, especially on the carpeted floor, and make sure the air vents are smooth;
♥ Thoroughly clean the treatment head regularly to keep it clean, so as not to cause the laser output to weaken, you can use lens paper or cotton swabs dipped in anhydrous ethanol (95% alcohol) or special lens cleaner to gently wipe;
♥ Do not use flammable materials to clean and sterilize the treatment head and treatment area during operation;
♥ Do not use gasoline, alcohol, thinner and other chemically treated rags to wipe the surface of the chassis;
♥ The complex internal structure of the instrument, it is strictly prohibited to disassemble by yourself, please be sure to contact our customer operations department in a timely manner when a malfunction occurs;
♥ In order to ensure the normal use of the instrument, the purchase or replacement of instrument accessories, please contact the manufacturer or agent directly.
work pattern | scan | CO ₂ |
Laser type | Seoff DC CO laser | |
output energy | 1 —30W | 1W-30W (to 1W Forward) |
Output method | Scan circle maximum diameter:20mm Minimum diameter:0.1mm | Pulse super pulse single pulse continuous |
Maximum area of the scan rectangle:20*20 Minimum area:0.1*0.1 | ||
Aim at the light | Aiming light red semiconductor indicatorlight (650nm) | |
navar | Microcomputer control large screen color white touch display menu | |
Light road transmission | Seven-joint light guide arm | |
coolant passage | Closed internal circulating water for cooling | |
outline dimension | 850mm × 600mm ×490mm | |
weight | 30kg | |
source | AC 220V ,50/60HZ 10A |
Batch customization:
Marketing support:
Appearance customization:
Software interface customization:
Accessory customization:
Safety features are customized:
Customization of software functions:
Delya provides professional OEM/ODM customization service to help you build your own smart beauty device product line. With our rich industry experience, patented technologies and mature supply chain system, we are able to fulfill your needs in terms of product design, functionality and quality. Choose Delya to make your brand stand out in the competitive market!
Through customization, customers can create one-of-a-kind products and increase their competitiveness in the market by up to 30%.
Customized products effectively showcase the brand image, with 70% of consumers reporting a more favorable perception of the brand. This results in a 25% increase in overall brand value.
Customized services can be tailored to precisely meet a customer's unique needs. Customer satisfaction increased by 40%.
The added value of customized products is typically 50% higher. This significant increase in value directly leads to a 60% increase in the client's profitability.
Adopt aviation packing box and waterproof winding film to protect the goods in all aspects. Various modes of transportation are available to ensure that goods are delivered within 7 days.
Provide market data, operation program, operation training, marketing support and price protection to boost marketing.
We offer 24/7 service, resolving after – sales issues within 1 hour. The mainframe has a 2 – year warranty. With Japan and Europe offices and service centers, we ensure seamless global support.
Provide detailed manuals and professional operation videos, customers can learn according to the manuals can be skillful.
Because our factories meet ISO quality management requirements, Delya’s products are manufactured in accordance with CE, MSDS, RoHS, and FCC standards. Over the years, we have obtained numerous certifications to provide you with effective product quality assurance.
1.How long does it take for the skin to return to normal after treatment?
The recovery time of the skin after treatment varies from individual to individual. Generally speaking, the treated area will turn white or gray immediately after the procedure, accompanied by a painful burning sensation, which disappears a few hours after the procedure, and the scabs will start to form in 2-3 days and fall off naturally in about 1-2 weeks. After the scabs fall off, the skin basically returns to its normal appearance, but the internal collagen regeneration can last up to 6 months or even 3 years, during which the skin will continue to improve and become firmer and smoother.
2.Does fractional CO2 machine treatment hurt? What measures can be taken to alleviate the pain?
There is a certain amount of pain during the treatment, and the exact sensation varies from person to person. In order to alleviate the pain, the doctor will usually communicate fully with the patient before the treatment and adjust the treatment parameters according to the patient’s pain tolerance level. If the patient feels obvious pain during the treatment, he/she can inform the doctor, who will reduce the energy and other parameters appropriately. If the patient feels burning pain after the procedure, an ice pack can be used to relieve the pain.
3.Can I use skin care products after treatment? How long can I use them?
Avoid water and do not recommend using skin care products for 3 days after the treatment. 3 days later, according to the skin’s recovery, you can use mild, non-irritating medical skin care products, such as moisturizing and repairing creams or lotions, to help replenish the skin’s moisture and promote repair. After the scabs fall off, you can gradually resume the use of daily skincare products, but you need to avoid the use of products containing irritating ingredients (such as alcohol, fragrances, high concentration of fruit acids, etc.), and it is recommended to choose skincare products with moisturizing and repairing effects, and continue to use them for about 3 months, to help the skin to maintain a stable state.
4.How many times do I need to do CO2 laser treatment machine treatment? How often is it better to do it?
In the case of acne pits and depressed scars, for example, 3 – 5 treatments are usually required. The interval between each treatment is 1 – 3 months, depending on the individual’s skin recovery and the doctor’s recommendation. This is because it takes time for the skin to repair and regenerate, too short an interval may cause excessive stimulation to the skin and affect the recovery effect; while too long an interval may affect the overall treatment process and effect.
5.What is the difference between treatment and other laser cosmetic programs?
Compared with pixel laser, each laser beam of is brand new, with extremely small spot and fast emission speed, which can be emitted in a time-lagged state to give the skin a buffer time to bear the heat, and performs better in relieving pain and minimizing side effects. Pixel laser, on the other hand, by installing a sieve image generator in front of the emitter, rigidly splits the laser beam into multiple small laser beams, which only disperses the energy of the laser beam, the heat is still applied to the skin at the same time, and does not have the software operation functions such as intelligence and multiple graphics. Compared with other laser cosmetic programs, focuses more on the deep repair and regeneration of the skin, and is more effective in improving problems such as acne pits, scarring and wrinkles.